Brand Name : Emerson CONTROL TECHNIQUES

Model Number : EBU02

Certification : CE

Place of Origin : CHINA

MOQ : 1

Price : Contact us

Payment Terms : T/T / Paypal

Supply Ability : 50

Delivery Time : 2-3 work days

Packaging Details : New Original Box

Model : EBU02

Type : Battery Detector

Input voltage range : 80~320Vdc

Power consumption : <15W

Relative humidity : 10%RH ~ 90%RH

Ambient temperature : -10 ~ +50°C

Brand : Control Techniques

Weight : 2 kg

Contact Now

Battery Detector EBU02 Emerson Nidec Control Techniques MONITORING UNIT NEW in stock



Description

The Emerson battery detector is applicable to detecting batteries in power plants and transformer substation. It has two models: EBU01 and EBU02. The small size makes it suitable to be installed in a small space of electric cabinets.

Functions of EBU01 battery detector
1. EBU01 can detect temperature of two routes, current of one route, voltage of 24 battery cells. EBU02 can detect voltage of 19 battery cells.
2. The battery detector can adjust the measurement levels (2V, 6V, 12V) automatically according to the battery cell voltage, so as to improve the measurement accuracy.
3. Upon battery detector start, if the voltage of any detecting channel exceeds approximately 36V, the battery detector will shut down all the channels and stop the test. The alarm indicator will flash. The test will resume only when the power is cut off and the fault is cleared.
4. During the test process, if the voltage of any detection channel exceeds approximately 16.7V, the battery detector will shut down all the channels, stop the measurement and reset itself automatically. If the measurement voltage exceeds 16.7V after the reset, the preceding process will repeat. The alarm indicator will flash during the reset process. The battery detector will resume automatically after the overvoltage is removed.

EMU10 Monitoring System


The EMU10 includes the monitoring circuit inside the power module, the controller module (EMU10), distribution
monitoring units (EAU01, EDU01 and EGU01) and ISD (JYM-II and JYM-S2, or EDU01 and EGU01), and BMS
(EBU01and EBU02),
The EMU10 collects information from downstream monitoring devices, and then displays the information, generates alarms or sends control commands to the downstream monitoring devices after performing analysis and calculation to the collected information.
A built-in monitoring board monitors the rectifier, the AC distribution monitoring module EAU01, DC distribution monitoring module EDU01 and generic distribution monitoring module EGU01 monitor the system power distribution.
The system insulation status is monitored by EDU01 working with EGU01, or ISD. The battery connected to the system is monitored by the batter detector
The analog signal and digital signal of EMU10 are collected, calculated and sent to the controller by data collecting devices such as EAU01, EDU01, EGU01 (or master ISD JYM-Ⅱ + slave ISD) and BMS EBU01 or EBU02, and the controller will display these signals or issue alarms. The analog and digital signals introduced in the following are theoretically the maximum quantities that can be monitored. In actual situation, the number may vary with different settings.
System Functions
Perform battery auto BC/FC management, current limiting charge management, temperature1 Battery management compensation and battery capacity checking testaccording to the user’s settings on BC to FC or FC to BC parameters.
Perform BC protection to the battery according to the auto BC protection time set by the user
RS232/RS485 communication with host using MODBUS or CDT91 protocol, user can select the protocol according to actual needs.
Using memory disk can upgrade the application software, and can also import or export theconfiguration file.

Specification of EBU01 (EBU02 )battery detector
The specification of BD is shown in the following table.
DB specification
Parameter
Range
Error
Remark
Input voltage range

80 ~ 320Vdc
Power consumption
<15W
Ambient temperature
-10 ~ +50°C
Relative humidity
10%RH ~ 90%RH
Atmospere
70 ~ 106kPa
Dimensions
135mm%90mm%75mm
Weight
About 2kg
Communication baud rate
9600bps
Battery string voltage
80 ~ 320V
± 0.3%
The sum of all battery cells voltages
One route of battery current
-4 ~ 4V, Hall sensor measurement range -3000 ~ 3000A
± 0.5%
For EBU01
Two routes of battery temperature
-25 ~ 75℃
± 1℃
Voltage of battery cells 1 ~ 24
0.100 ~ 16.500V
± 0.2%
Voltage of battery cells 1 ~ 19
0.100 ~ 16.500V
± 0.2%
For EBU02
SP Drives
SP0401 SP0402 SP0403 SP0404 SP0405 SP1401 SP1402 SP1403
SP1404 SP1405 SP1406 SP2201 SP2202 SP2401 SP2402 SP2403
SP2404 SP3401 SP3402 SP3403 SP4401 SP4402 SP4403 SP5401
SP5402 SP5403 SP6401 SP6402 SP5402 ES2401 ES2402 ES2403
UNI Drives:
UNI1201 UNI1202 UNI1203 UNI1204 UNI1205 UNI2201 UNI2202 UNI2203
UNI3201 UNI3202 UNI3203 UNI3204 UNI1401 UNI1402 UNI1403 UNI1404
UNI1405 UNI2401 UNI2402 UNI2403 UNI3401 UNI3402 UNI3403 UNI3404
UNI3405 UNI4401 UNI4402 UNI4403 UNI4404 UNI4405 UNI5401 SP5402

Analog Input Cards and Termination Blocks
Description Model Number
8 Channels 4-20 mA, HART Standard I/O Termination Block VE4003S2B1
Redundant Standard I/O Termination Block
VE4033S2B1
Fused I/O Termination Block VE4003S2B2
4-wire I/O Termination Block VE4003S2B3
16-Pin Mass Termination Block VE4003S2B4
24-Pin Mass Termination Block VE4003S2B5
16 Channels 4-20 mA, HART Standard I/O Termination Block VE4003S2B6
4-wire I/O Termination Block 16 Channels 4-20 ma, HART, Plus Card VE4003S2B7
16-Channel 2-Wire AI Terminal Block for Series 2 Plus VE4003S2B9
16-Channel 4-Wire AI Terminal Block for Series 2 Plus VE4003S2B10
Redundant 16-Channel 2- & 4-Wire AI Terminal Block for Series 2 Plus VE4033S2B10
8 Channels Thermocouple,mV Standard I/O Termination Block VE4003S4B1
Cold Junction Compensated (CJC) Termination Block VE4003S5B1

Analog Input Card: 8 Channels RTD
Resistant Temperature Device (RTD) Termination Block

VE4003S6B1
Isolated Input Card
Isolated Input Terminal Block
VE4003S7B1
Standard I/O Termination Block VE4005S2B1
Redundant Standard I/O Termination Block VE4035S2B1
Fused I/O Termination Block VE4005S2B2
16-Pin Mass Termination Block VE4005S2B3
16-Channel AO Terminal Block for Series 2 Plus VE4005S2B4
Redundant 16-Channel AO Terminal Block for Series 2 Plus VE4035S2B4

Standard I/O Termination Block

VE4001S2T1B1
Fused I/O Termination Block VE4001S2T1B2
Standard I/O Termination Block VE4001S2T2B1
Redundant Standard I/O Termination Block VE4031S2T2B1
Fused I/O Termination Block
VE4001S2T2B2
16-Pin Mass Termination Block VE4001S2T1B3
16-Pin Mass Termination Block VE4001S2T2B3
Standard Termination Block VE4001S2T2B4
40-pin Mass Termination Block
VE4001S2T2B5
Redundant32-Channel DI Terminal Block for Series 2 Plus VE4031S2T2B6
40-pin DI Mass Termination Block for Series 2 Plus (to be used with P+F HiD or HiC IS barriers and termination boards for DeltaV DCS)
VE4001S2T2B7
40-pin DI Mass Termination Block for Series 2 Plus including 2 x 16-channel DI Plus Mass Connection Boards*
VE4051S2T2B7
Redundant 40-pin DI Mass Termination Block for Series 2 Plus (to be used with P+F HiD or HiC IS barriers and termination boards for DeltaV DCS)
VE4031S2T2B7
Redundant 40-pin DI Mass Termination Block for Series 2 Plus including 2 x 16-channel DI Plus Mass Connection Boards *
VE4081S2T2B7
Standard I/O Termination Block VE4001S3T1B1
Fused I/O Termination Block VE4001S3T1B2
Standard I/O Termination Block VE4001S3T2B1
Fused I/O Termination Block VE4001S3T2B2
Discrete 32 Channel Terminal Block VE4015
Discrete 32-Channel Terminal Block
VE4001S5T2B4
40-pin Mass Terminal Block VE4001S5T2B5
Standard I/O Termination Block VE4002S1T1B1
Fused I/O Termination Block VE4002S1T1B2
16-Pin Mass Termination Block VE4002S1T1B3
Standard I/O Termination Block
VE4002S1T2B1
Redundant Standard I/O Termination Block VE4032S1T2B1
Fused I/O Termination Block VE4002S1T2B2
16-Pin Mass Termination Block VE4002S1T2B3
10-Pin Mass Termination Block VE4002S1T2B4
Standard I/O Termination Block VE4002S1T2B5
40-Pin Mass Termination Block VE4002S1T2B6
40-pin DO Mass Termination Block for Series 2 Plus (to be used with P+F HiD or HiC IS barriers and termination boards for DeltaV DCS)
VE4002S1T2B8
40-pin DO Mass Termination Block for Series 2 Plus including 4 x 8-channel DO Mass Connection Boards *
VE4052S1T2B8
Redundant 40-pin DO Mass Termination Block for Series 2 Plus (to be used with P+F HiD or HiC IS barriers and termination boards for DeltaV DCS)
VE4032S1T2B8
Redundant 40-pin DO Mass Termination Block for Series 2 Plus including 4 x 8-channel DO Mass Connection Boards *
VE4082S1T2B8
Standard I/O Termination Block VE4002S2T1B1
Fused I/O Termination Block VE4002S2T1B2
Standard I/O Termination Block
VE4002S2T2B1
Fused I/O Termination Block VE4002S2T2B2
250V 2A Fuse for Fused Terminal Block; Box of 20
KJ4010X1-BC1


Our advantage Products:

【Honeywell】Module DCS / PLC
【Emerson / Delta V】Module
【ABB】Input Output Module
【AB】Module / Touch Screen
【Rosemount】Pressure and Temperature Transmitter
【Yokogawa】Pressure Transmitter
【Yaskawa】Servo Drive / Servo Motor
【GE/Fanuc】IC69 Series PLC
【Mitsubishi】Servo Drive / Servo Motor
(Modicon,SMC,SICK,NORGREN,Siemens etc.)




Company Introduction
Battery Detector EBU02 Emerson Nidec Control Techniques MONITORING UNIT NEW in stock


Product Tags:

ac servo pack

      

ac servo drive

      
Wholesale Battery Detector EBU02 Emerson Nidec Control Techniques MONITORING UNIT NEW in stock from china suppliers

Battery Detector EBU02 Emerson Nidec Control Techniques MONITORING UNIT NEW in stock Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Wisdomlong Technology CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)